<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-08 22-46-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 68 kHz 15620 11,0243
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 5,10 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 68 kHz MIN: 10 kHz % above 76 kHz: 11,0243 Acquired: 2025/04/08 22.45.37 Total samples: 15620 Equivalent time: 0:13:01 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,7 dBr MIN: 4,2 dBr AVE: 5,10 dBr % above 12,2 dBr: 0,0 Last value: 4,9 dBr (2025/04/08 22.45.37) 22.32 22.34 22.36 22.38 22.40 22.42 22.44 0 2 4 6 Pm [dBr]